A restroom is often the smallest room in a shop, office or restaurant, and for a business it is one of the most tightly defined. Public accommodations and commercial facilities must follow the 2010 ADA Standards for Accessible Design, and the U.S. Access Board's guide to those standards notes that in new construction, access is required to all toilet rooms, including those for employees. The rules settle the layout early, which leaves finishes and fixtures free to carry the character of the space.

Start with the floor plan, not the tile

The Standards do not set a room size. As the Access Board guide explains, size follows from the fixtures, their clearances, the turning space and the swing of the door. Three dimensions do most of the work:

  • Clearance at the toilet: 60 inches minimum measured from the side wall and 56 inches minimum from the rear wall.
  • Turning space: a 60-inch circle, or a T-shaped space within a 60-inch square.
  • The door: a clear opening of 32 inches minimum. The door may swing into the turning space. It may also swing into the clearance at a fixture where the room is for individual use and has a clear floor space of at least 30 by 48 inches beyond the arc of the door swing.

Settle these first. Outside residential units, the sink cannot overlap the toilet clearance, so the Access Board notes that with the two side by side, the plumbing wall is typically set by that clearance plus the width of the sink and any clearance beyond it, unless the sink is recessed.

The toilet and its grab bars

The toilet's centerline sits 16 to 18 inches from the side wall, and the seat height is 17 to 19 inches to the top of the seat. Flush controls go on the open side.

Grab bars are required beside and behind the toilet:

  • Side wall: 42 inches long minimum, no more than 12 inches from the rear wall, extending at least 54 inches from it.
  • Rear wall: 36 inches long minimum, reaching at least 12 inches to one side of the toilet's centerline and 24 inches to the other.
  • Height: 33 to 36 inches above the floor to the top of the gripping surface.
  • Spacing: exactly 1 1/2 inches from the wall, with 12 inches minimum clear above the bar.

Round bars may be 1 1/4 to 2 inches in diameter, and the bar, its fasteners and the supporting structure must withstand a 250-pound force. Because grab bars are fixed and visible, it is worth choosing them with the faucet and accessories as part of the finish palette. Plan the toilet paper holder too: its centerline is 7 to 9 inches in front of the toilet, its outlet 15 to 48 inches above the floor, and never behind a grab bar.

Choosing the sink and vanity

The front of the rim or counter can be no higher than 34 inches above the floor, and a forward approach needs knee and toe clearance below, 30 inches wide minimum. Pipes under the sink must be insulated or otherwise protected against contact, with no sharp or abrasive surfaces beneath. That points toward a wall-hung basin, a floating counter or a console sink with open space below, rather than a closed vanity cabinet that fills the space under the basin.

Faucet controls must work with one hand, without tight grasping, pinching or twisting of the wrist, and with no more than 5 pounds of force.

Mirror and shelves

A mirror over the sink needs the bottom of its reflecting surface no higher than 40 inches above the floor; one hung elsewhere, 35 inches. Shelves sit between 40 and 48 inches above the floor.

The door and its hardware

Handles, pulls, latches and locks must be operable with one hand without tight grasping or twisting, and mounted between 34 and 48 inches above the floor. A unisex single-user restroom also needs a privacy latch.

When the restroom is being renovated, not built

In alterations, the Standards apply according to the scope of work. If only some elements in a restroom are altered, only those elements must comply; if the room is completely altered, the whole room must. The Access Board guide adds that altering several elements at once may be a cost-effective opportunity to make the entire room accessible.

What it means for a business in Lexington

For a shop, office or restaurant in Lexington, the restroom deserves the same thought as the front of house. Build the plan around the clearances first, choose a sink and grab bars that belong to the finish scheme, and confirm the details with your architect and local building officials before work begins. There are more ideas for commercial spaces and bathrooms, and if a restroom is on your list, you are welcome to get in touch.

Sources

Keep reading

Related reading

New posts by email

The newest design notes, project stories and sourcing ideas from the studio, once a day or once a week.

How often

Begin

Let's Create Something Timeless

Whether you're planning a full home renovation, a single room refresh, or a commercial space that reflects your brand's character, we'd be honored to discuss your project.

Start a Conversation
Built with love by Stacklumen